Meta tags:
keywords= iah, IAH, international arabian hardware;
Headings (most frequently used words):
monitoring, environment, system, enterprise, power, server, for, systems, low, cost, control, with, remote, product, perspective, small, medium, large, legacy, management, software, environmentmonitoring, mini, monitoringand, devices, ac, voltage, detector, relay, secure, unit, environmental, reboot, switch, further, details, please, visit, www, nti, sa, com, riyadh, head, quarter,
Text of the page (most frequently used words):
and (38), the (23), system (21), for (18), via (18), power (17), usb (17), monitoring (13), #control (12), enviromux (12), #devices (12), external (12), with (11), sensors (11), network (10), voice (10), available (9), internal (9), configurable (9), web (8), when (8), environment (8), you (7), ping (7), modem (7), server (6), options (6), monitor (6), temperature (6), email (6), page (6), snmp (6), current (6), voltage (6), output (6), inputs (6), battery (6), sensor (6), reboot (5), supports (5), humidity (5), relay (5), digital (5), linux (5), goes (5), out (5), range (5), threshold (5), will (5), notify (5), phone (5), calls (5), automatic (5), dialer (5), sms (5), messages (5), backup (5), enterprise (5), all (4), nti (4), remote (4), from (4), dual (4), line (4), leds (4), port (4), standard (4), features (4), ports (4), inside (4), units (4), management (4), flash (4), 1ru (4), rackmount (4), contact (3), riyadh (3), allows (3), off (3), other (3), device (3), software (3), application (3), interface (3), 10a (3), secure (3), environmental (3), vac (3), alerts (3), din (3), mounting (3), relays (3), also (3), includes (3), alarm (3), beacon (3), siren (3), supply (3), iahksa (2), projects (2), tutela (2), about (2), home (2), com (2), 0096 (2), 611 (2), remotely (2), powered (2), auto (2), multiple (2), telnet (2), protection (2), cord (2), low (2), cost (2), unit (2), 120v (2), nema (2), universal (2), 250v (2), iec (2), c14 (2), detector (2), connected (2), sensing (2), mini (2), traps (2), visual (2), indicator (2), red (2), led (2), mng (2), 16d (2), sems (2), statuses (2), windows (2), 2000 (2), systems (2), three (2), drive (2), 48vdc (2), 24vdc (2), case (2), are (2), modems (2), drives (2), fiber (2), kit (2), rights, reserved, 2018, designed, heartsuit, glaubetech, fax, 472, 1099, tel, 292, 2397, box, 28615, 11447, head, quarter, pwr, rmt, rbt, over, scheduler, scheduling, events, unlimited, number, switches, one, autoping, dxp, dataprobe, exchange, protocol, addresses, password, separate, user, administrator, passwords, 12a, country, specific, switch, servers, any, location, rs232, ssh, including, water, detection, sends, alert, notifications, syslog, models, support, overload, circuit, breaker, frequency, factor, 15a, c13, input, connectors, detects, 250, dry, closes, above, opens, below, plug, socket, lxo, industrial, high, environments, 167, intuitive, graphical, that, provides, easy, use, unified, both, configuring, 000, can, display, values, individual, list, may, monitored, configured, individually, group, actively, polls, status, information, well, listens, client, communicates, read, deploy, configuration, changes, compatible, vista, 20003, 20008, solaris, freebsd, mac, optional, gsm, legacy, optic, connecting, large, two, medium, small, further, details, please, visit, www, product, perspective, iah,
Text of the page (random words):
nti iah home current about tutela current nti current projects current contact current product perspective environment monitoring systems for further details please visit www nti sa com small enterprise server environment monitoring system the enviromux 2d supports 2 external configurable sensors 5 digital inputs and 1 output relay for control of external devices it features 2 usb ports for usb modem or usb flash drive linux inside monitor ping up to 16 ip network devices when a sensor goes out of range of a configurable threshold the system will notify you via email snmp traps web page alerts a visual indicator red led voice phone calls via automatic voice dialer system and sms messages via usb 3g modem options available din mounting internal backup battery and 1ru rackmount kit medium enterprise environment monitoring system the enviromux 5d supports 5 external configurable sensors 5 digital inputs and 2 output relays for control of external devices the system also includes two internal sensors temperature and humidity it features 4 usb ports for usb modems or usb flash drives linux inside monitor ping up to 64 ip network devices when a sensor goes out of range of a configurable threshold the system will notify you via email leds alarm beacon siren web page network management snmp voice phone calls via automatic voice dialer system and sms messages via external usb 3g modem options available din mounting internal backup battery dual power supply and 1ru rackmount kit large enterprise environment monitoring system the enviromux 16d supports 16 external configurable sensors 8 digital inputs and 4 output relays for control of external devices the system also includes three internal sensors temperature humidity and power it features 4 usb ports for usb modems or usb flash drives linux inside monitor ping up to 64 ip network devices when a sensor goes out of range of a configurable threshold the system will notify you via email leds alarm beacon siren web page network management snmp voice phone calls via automatic voice dialer system and sms messages via external usb 3g modem options available dual power supply 24vdc or 48vdc power and fiber optic port for connecting to fiber network internal backup battery and 1ru rackmount case are standard legacy enterprise environment monitoring system the enviromux sems 16 supports 16 external configurable sensors 8 digital inputs and 4 output relays for control of external devices the system also includes three internal sensors temperature humidity and power it is available with an optional usb port for usb modem or usb flash drive monitor ping up to 64 ip network devices when a sensor goes out of range of a configurable threshold the system will notify you via email leds alarm beacon siren web page network management snmp voice phone calls via automatic voice dialer system and sms messages via external gsm or 3g modem options available usb port 48vdc or 24vdc power and dual power supply internal backup battery and 1ru rackmount case are standard management software for enterprise environment monitoring systems the enviromux mng is an intuitive graphical software that provides an easy to use unified interface for both monitoring and configuring up to 3 000 enviromux 2d 5d 16d and enviromux sems 16 u units and all connected sensors it can display values and statuses for individual sensors or a list of sensors multiple enviromux units may be monitored and configured individually or in a group the server application actively polls all units for status information as well as listens for alerts from all units the client application communicates with the server to read statuses and to deploy configuration changes the enviromux mng is compatible with windows 2000 xp vista 7 8 windows server 2000 20003 20008 solaris linux freebsd and mac os 9 10 low cost environment monitoring system mini server environment monitoring system the enviromux mini lxo features 2 temperature humidity ports 5 digital inputs and 1 output relay for control of an external device linux inside monitor ping up to 16 ip network devices when a sensor goes out of range of a configurable threshold the system will notify you via email snmp traps web page alerts a visual indicator red led voice phone calls via automatic voice dialer system and sms messages via usb 3g modem options available internal backup battery din mounting and industrial system for high temperature environments up to 167 f 75 c power monitoring and power control devices ac voltage detector with relay the enviromux ac voltage detector with relay detects voltage from 50 to 250 vac when connected to an environmental monitoring system with dry contact inputs battery sensor or other device the internal relay closes when sensing voltage above 60 vac and opens when sensing voltage 55 vac and below available with a standard us 120v 10a nema 5 15 plug or universal 250v iec c14 socket secure remote power control unit with environmental monitoring the enviromux secure remote power control unit allows you to remotely reboot and control power on off to up to 8 servers or other powered devices from any location via secure web interface rs232 ssh or telnet monitor ping up to 8 ip network devices supports 2 environmental sensors including temperature humidity and water detection sends alert notifications via email syslog leds web page and snmp the 4 8 port models support overload protection via circuit breaker and current line voltage line frequency and power factor monitoring available with standard us 120v 15a nema 5 15 or universal 250v 10a iec c14 c13 input and output connectors low cost remote power reboot switch the pwr rmt rbt lc allows you to remotely reboot and control power on off to a server or other powered device over ip auto scheduler allows for scheduling power on off reboot events control an unlimited number of remote power reboot switches from one software application multiple control options web interface autoping telnet dxp dataprobe exchange protocol auto ping up to 2 ip addresses dual password protection with separate user and administrator passwords available with 12a us line cord or 10a country specific line cord riyadh head quarter po box 28615 riyadh 11447 tel 0096 611 292 2397 fax 0096 611 472 1099 riyadh iahksa com home about tutela nti projects contact all rights reserved 2018 by iahksa designed heartsuit glaubetech
|